2031

3


Program not found

Object program for process execution was not found.


1. Check if the wrong program number is designated.

2. Check if a program was loaded after it was transmitted or compiled.

3. Check if a transmit error occurs when the execution form file is sent from WINCAPSII to the controller.

4. Check if an error has occurred during compiling by the controller.

5. Create the execution form file again by using WINCAPSII or the controller. Disable the DATE INSPECTION option in WINCAPSII at this time.

6. Check if the status of the command area and the data area are settled when the strobe signal rises in the standard mode.

7. Check if the program select signal status is settled when the program start signal rises in the compatible mode.